Aquam8012A-1U-10T-H2-H2 | 302242622 | 10 x 10/100Base-TX ports, 72-110VDC(50.4-137.5VDC) ,single power inputs, -40°C to +75°C operating temperature |
Aquam8012A-1U-2GE8T-H2-H2 | 302242621 | 2 x 10/100/1000Base-TX ports , 8 10/100Base-TX ports, 72-110VDC(50.4-137.5VDC) ,single power inputs, -40°C to +75°C operating temperature |
Aquam8012A-3GE9P-WV-WV | 302242612 | 3 x 10/100/1000Base-TX ports, 9 10/100Base-TX ports including 9 802.3at POE ports, 24-110VDC(16.8-154VDC) dual redundant power inputs, -40°C to +75°C operating temperature |
Aquam8012A-3GE9T-H6-H6 | 302242610 | 3 x 10/100/1000Base-TX ports, 9 10/100Base-TX ports, 72-110VDC(50.4-137.5VDC) dual redundant power inputs, -40°C to +75°C operating temperature |
Aquam8012A-3GE9T-L13-L13 | 302242619 | 3 x 10/100/1000Base-TX ports, 9 10/100Base-TX ports, 24VDC(16.8-30VDC) dual redundant power inputs, -40°C to +75°C operating temperature |
Aquam8012A-3GE9T-L14-L14 | 302242611 | 3 x 10/100/1000Base-TX ports, 9 10/100Base-TX ports, 48VDC(33.6-60VDC) dual redundant power inputs, -40°C to +75°C operating temperature |
Aquam8012A-4GE8P-WV-WV | 302242615 | 4 x 10/100/1000Base-TX ports, 8 10/100Base-TX ports including 8 802.3at POE ports, 24-110VDC(16.8-154VDC) dual redundant power inputs, -40°C to +75°C operating temperature |
Aquam8012A-4GE8T-H6-H6 | 302242613 | 4 x 10/100/1000Base-TX ports, 8 10/100Base-TX ports, 72-110VDC(50.4-137.5VDC) dual redundant power inputs, -40°C to +75°C operating temperature |
Aquam8012A-4GE8T-L13-L13 | 302242620 | 4 x 10/100/1000Base-TX ports, 8 10/100Base-TX ports, 24VDC(16.8-30VDC) dual redundant power inputs, -40°C to +75°C operating temperature |
Aquam8012A-4GE8T-L14-L14 | 302242614 | 4 x 10/100/1000Base-TX ports, 8 10/100Base-TX ports, 48VDC(33.6-60VDC) dual redundant power inputs, -40°C to +75°C operating temperature |
Aquam8012A-9P-WV-WV | 302242601 | 9 x 10/100Base-TX ports including 9 802.3at POE ports, 24-110VDC(16.8-154VDC) dual redundant power inputs, -40°C to +75°C operating temperature |
Aquam8012A-9T-H6-H6 | 302242602 | 9 x 10/100Base-TX ports, 72-110VDC(50.4-137.5VDC) dual redundant power inputs, -40°C to +75°C operating temperature |
Aquam8012A-9T-L13-L13 | 302242616 | 9 x 10/100Base-TX ports, 24VDC(16.8-30VDC) dual redundant power inputs, -40°C to +75°C operating temperature |
Aquam8012A-9T-L14-L14 | 302242603 | 9 x 10/100Base-TX ports , 48VDC(33.6-60VDC) dual redundant power inputs, -40°C to +75°C operating temperature |
Aquam8012A-B-3GE9P-WV-WV | 302242606 | 3 x 10/100/1000Base-TX ports including 2 ports with Bypass, 9 10/100Base-TX ports including 9 802.3at POE ports, 24-110VDC(16.8-154VDC) dual redundant power inputs, -40°C to +75°C operating temperature |
Aquam8012A-B-3GE9T-H6-H6 | 302242604 | 3 x 10/100/1000Base-TX ports including 2 ports with Bypass, 9 10/100Base-TX ports, 72-110VDC(50.4-137.5VDC) dual redundant power inputs, -40°C to +75°C operating temperature |
Aquam8012A-B-3GE9T-L13-L13 | 302242617 | 3 x 10/100/1000Base-TX ports including 2 ports with Bypass, 9 10/100Base-TX ports, 24VDC(16.8-30VDC) dual redundant power inputs, -40°C to +75°C operating temperature |
Aquam8012A-B-3GE9T-L14-L14 | 302242605 | 3 x 10/100/1000Base-TX ports including 2 ports with Bypass, 9 10/100Base-TX ports, 48VDC(33.6-60VDC) dual redundant power inputs, -40°C to +75°C operating temperature |
Aquam8012A-B-4GE8P-WV-WV | 302242609 | 4 x 10/100/1000Base-TX ports including 4 ports with Bypass, 8 10/100Base-TX ports including 8 802.3at POE ports, 24-110VDC(16.8-154VDC) dual redundant power inputs, -40°C to +75°C operating temperature |
Aquam8012A-B-4GE8T-H6-H6 | 302242607 | 4 x 10/100/1000Base-TX ports including 4 ports with Bypass, 8 10/100Base-TX ports, 72-110VDC(50.4-137.5VDC) dual redundant power inputs, -40°C to +75°C operating temperature |
Aquam8012A-B-4GE8T-L13-L13 | 302242618 | 4 x 10/100/1000Base-TX ports including 4 ports with Bypass, 8 10/100Base-TX ports, 24VDC(16.8-30VDC) dual redundant power inputs, -40°C to +75°C operating temperature |
Aquam8012A-B-4GE8T-L14-L14 | 302242608 | 4 x 10/100/1000Base-TX ports including 4 ports with Bypass, 8 10/100Base-TX ports, 48VDC(33.6-60VDC) dual redundant power inputs, -40°C to +75°C operating temperature |
| | |