Lantech IPES-3424DSFP-2P Series

IPES-3424DSFP-2P Series

24 x 10/100BaseTX PoE at + 4 Dual Speed SFP L2+ Industrial Managed Switch

 

Categories: , ,

Overview

Lantech IPES-3424DSFP-2P is a high performance L2 + PoE managed industrial switch which provides L2 wire speed and advanced security function for network aggregation and backbone deployment. It delivers ITU G.8032 enhanced ring recovery less than 20ms including dynamic coupling ring, and enhanced mode for easy configuration, comprehensive QoS, QoS by VLAN, advanced security including INGRESS/EGRESS ACL L2/L3, SSH/SSL, Mac based DHCP server, DHCP Option 82, DHCP server, IGMPv1/v2/v3/router port, QinQ* (double tag VLAN) which are important features required in train and large network. It also supports Cisco Discovery Protocol (CDP) and LLDP for Ciscoworks to detect the switch info and show on L2 map topology.

Compliant with IEEE802.3at/af standard, the Lantech IPES-3424DSFP-2P is able to feed each PoE port up to 30Watts@54VDC providing the connected PD devices at Gigabit speed. It also supports advanced PoE management including PoE detection and scheduling. PoE detection can detect if the connected PD is still alive then sending power; PoE scheduling is to allow pre-set power feeding schedule upon routine time table. Per port PoE status explicits voltage, current, watt and poe temperature information.

Lantech IPES-3424DSFP-2P features enhanced G.8032 ring which can be self-healed in less than 20ms for single ring topology protection covering Multicast packets. It also supports various ring topologies that covers double ring, multi-chain (under enhanced ring), train ring, basic ring by easy setup than others. The innovative auto-Ring configurator (auto mode) can calculate owner and neighbor in one step. It supports MSTP that allows RSTP over Vlan for redundant links with 8/16* MSTI.

The IPES-3424DSFP-2P also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech IPES-3424DSFP-2P is able to alert with the LED indicator and send out an email, traps or a SMS text. Repowered auto ring restore function (node failure protection) ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. This feature prevents the broken ring and keep ring alive without any re-configuration needed when power back. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.

The IPES-3424DSFP-2P DIDO function can support additional open/close physical contact for designate applications besides Port / Power events, for example, DIDO function can trigger alarm if the switch was moved or stolen. In case of events, the IPES-3424DSFP-2P will immediately send an email, SMS text to pre-defined addresses as well as SNMP Traps out. It provides 2DI and 2DO while disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors into the auto alarm system and transfer the alarm information to IP network with email, text and SNMP.

Lantech IPES-3424DSFP-2P supports PoE power inputs from DC45~56V with dual system power. It features high reliability and robustness withstanding extensive EMI/RFI phenomenon, lighting surge, inductive load switching, high ESD, high fault current environment usually found in Substation, Steel automation, Mining and Process control etc. Supporting the latest EEE (Efficient Energy Ethernet) standard, IPES-3424DSFP-2P can run under widely operational temperature (-40°C~75°C) in the harsh environment.

Features

  • 24 x 10/100BaseTX PoE at/af+ 4 100M/1000M SFP L2+
  • 16K MAC Address Table
  • Dual Power Supply Design for DC(9.5V~60VDC), AC(85V~265VAC) or 100V~370VDC
  • PoE power input with budget up to 720W
  • -40to 75C operation temperature(-E model)
  • PoE management including PoE detection and scheduling for PD (power devices); per Port PoE status includes voltage, current, watt and PoE temperature
  • DDM to support SFP diagnostic function***
    4K 802.1Q Vlan, Port Based VLAN,GVRP**,QinQ*,MVRP*
  • Port Trunk with LACP 127 trunks with automatic link failover
  • Repowered auto ring restore (node failure protection)
  • Auto ring configuration(auto mode) for single ring
  • Ring covers multicast on different ports
  • Auto topology drawing in web UI with detail node info
  • Auto configurator for auto ITU ring setup
  • 2 DI/DO and 1 relay contact alarm

Ordering Information

Part NumberArticle numberDescription
IPES-3424DSFP-2P8380-60224 x 10/100TX POE at/af + 4 Dual SFP L2 plus Industrial Switch Built-in 1x isolated DC 12~56VDC power supply + 1x additional power socket + 1x 48VDC PoE power input; -20°C to 60°C
IPES-3424DSFP-2P-E8380-60324 x 10/100TX POE at/af + 4 Dual SFP L2 plus Industrial Switch Built-in 1x isolated DC 12~56VDC power supply + 1x additional power socket + 1x 48VDC PoE power input; -40°C to 75°C
IPES-3424DSFP-2P-AC8380-60424 x 10/100TX POE at/af + 4 Dual SFP L2 plus Industrial Switch Built-in 1x isolated AC85~265VAC IEC320 power supply + 1x additional power socket + 1x 48VDC PoE power input; -20°C to 60°C
IPES-3424DSFP-2P-AC-E8380-60524 x 10/100TX POE at/af + 4 Dual SFP L2 plus Industrial Switch Built-in 1x isolated AC85~265VAC IEC320 power supply + 1x additional power socket + 1x 48VDC PoE power input; -40°C to 75°C
IPES-3424DSFP-2P-HV8380-60624 x 10/100TX POE at/af + 4 Dual SFP L2 plus Industrial Switch Built-in 1x isolated AC/DC 85~265VAC/100V~370VDC power supply + 1x additional power socket + 1x 48VDC PoE power input; -20°C to 60°C
IPES-3424DSFP-2P-HV-E8380-60724 x 10/100TX POE at/af + 4 Dual SFP L2 plus Industrial Switch Built-in 1x isolated AC/DC 85~265VAC/100V~370VDC power supply + 1x additional power socket + 1x 48VDC PoE power input; -40°C to 75°C

OPTIONAL ACCESSORIES – DIN Rail Power

Part NumberDescription
NDR-480 Series480W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)
NDR-240 Series240W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)
NDR-120 Series120W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C; For 115VAC, please refer to derating curve on NDR-120 Series datasheet)
NDR-75 Series75W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C; For 115VAC, please refer to derating curve on NDR-120 Series datasheet)

OPTIONAL ACCESSORIES – Mini GBIC (SFP)

Article NumberDescription
8330-060100Base FX 2KM, Multi-mode, LC Transceiver
8330-061100Base LX 30KM, Single-mode, LC Transceiver
8330-065100Base FX 5KM, Multi-mode, LC Transceiver
8330-068125Mbps BiDi SFP 20KM (WDM 1550) Transceiver
8330-069125Mbps BiDi SFP 20KM (WDM 1310) Transceiver
8330-071125Mbps BiDi SFP 2KM (WDM 1310) Transceiver
8330-072 125Mbps BiDi SFP 2KM (WDM 1550) Transceiver
8330-080125Mbps BiDi SFP 40KM (WDM 1310) Transceiver
8330-081125Mbps BiDi SFP 60KM (WDM 1310) Transceiver
8330-082 125Mbps BiDi SFP 40KM (WDM 1550) Transceiver
8330-083125Mbps BiDi SFP 60KM (WDM 1550) Transceiver
8330-084125Mbps BiDi SFP 80KM (WDM 1310) Transceiver
8330-085125Mbps BiDi SFP 80KM (WDM 1550) Transceiver
8330-198125Mbps BiDi SFP 60KM (WDM 1310) Transceiver
8330-162XMINI GBIC 1000SX (LC/0.5km) Transceiver
8330-163XMINI GBIC 1000SX2 (LC/2km) Transceiver
8340-0591MINI GBIC 1000LHX (LC/40km) Transceiver
8330-165XMINI GBIC 1000LX (LC/10km) Transceiver
8330-166MINI GBIC 1000XD (LC/50km) Transceiver
8330-167MINI GBIC 1000ZX (LC/80km) Transceiver
8330-168MINI GBIC 1000T (100m) Transceiver
8330-169MINI GBIC 1000XD (LC/60km) Transceiver
8330-170MINI GBIC 1000EZX (120km) Transceiver
8330-180LTSFP-1000BX-40KM Transceiver (WDM 1310)
8330-181LTSFP-1000BX-60KM Transceiver (WDM 1310)
8330-182LTSFP-1000BX-40KM Transceiver (WDM 1550)
8330-183LTSFP-1000BX-60KM Transceiver (WDM 1550)
8330-184LTSFP-1000BX-80KM Transceiver (WDM 1490)
8330-185LTSFP-1000BX-80KM Transceiver (WDM 1550)
8330-186LTSFP-1000BX-20KM Transceiver (WDM 1310)
8330-187LTSFP-1000BX-20KM Transceiver (WDM 1550)
8330-188LTSFP-1000BX-10KM Transceiver (WDM 1310)
8330-189LTSFP-1000BX-10KM Transceiver (WDM 1550)
8330-191Dual Speed SFP 100M/1000M-LX 10KM Transceiver
8330-1951.25Gbps BiDi SFP 2KM Transceiver (WDM 1310)
8330-1961.25Gbps BiDi SFP 2KM Transceiver (WDM 1550)
8330-1971.25Gbps BiDi SFP 0.5KM Transceiver (WDM 1310)

Downloads

Datasheet